We use cookies to offer the best possible user experience on our website. We also use third-party cookies, to deliver personalised advertisement messages. By using our website you agree, that cookies can be saved on your device. Further information on the cookies used and on how to disable them can be found here.
 
 
MAXIMA 900
  • Modular system with 122 models with 40, 80, 120, 160 cm modules.
  • Low environmental impact: reduced consumption and high efficiency.
  • Guaranteed quality and safety: IMQ and IMQ-GS certifications.
  • Maximum life with 3 years warranty.
 
BACK TO THE PRODUCT LIST>> 
boiling pans
Available in the direct heating version for cooking liquid food that does not need stirring and also in the indirect heating version (gas and electrical versions) for thicker foods, such as creams and sauces.
The AISI 316 steel tank is highly resistant to salt and sauce corrosion and can be even used by inserting baskets for cooking large amounts of vegetables. Cleaning and maintenance are easy, thanks to the rounded edges and the draining tap that can be removed easily. Any small residuals flow through the hole on the top.
Ask for more informations
100 L ELECTRIC BOILING PAN WITH INDIRECT HEATING
Code 20833000 - Mod E9P10I
Worktop, front and side panels made of AISI 304 stainless steel. Inside made of stainless steel.AISI 304 stainless steel cooking container with 15/10 thickness, AISI 316 stainless steel bottom with 20/10 thickness. Jacket with bottom and walls of AISI 304 stainless steel, bottom with 20/10 thickness, walls with 15/10 thickness. Indirect type heating with low pressure steam (0.5 bar) generated inside the jacket through armored resistance from Incoloy equipped with a safety thermostat. Hot and cold water taps on the worktop with an articulated spout for filling and washing the container and jacket. 2” draining tap of chromed brass with athermic handle. Mechanical gauge with a jacket pressure indicator. Power supply regulated by a 3-position switch. Separate control for temperature regulation. Pilot light and temperature indicator light. Doublewalled lid.
Continue Technical Sheet
150 L ELECTRIC BOILING PAN WITH INDIRECT HEATING
Code 20843000 - Mod E9P15I
Worktop, front and side panels made of AISI 304 stainless steel. Inside made of stainless steel.AISI 304 stainless steel cooking container with 15/10 thickness, AISI 316 stainless steel bottom with 20/10 thickness. Jacket with bottom and walls of AISI 304 stainless steel, bottom with 20/10 thickness, walls with 15/10 thickness. Indirect type heating with low pressure steam (0.5 bar) generated inside the jacket through armored resistance from Incoloy equipped with a safety thermostat. Hot and cold water taps on the worktop with an articulated spout for filling and washing the container and jacket. 2” draining tap of chromed brass with athermic handle. Mechanical gauge with a jacket pressure indicator. Power supply regulated by a 3-position switch. Separate control for temperature regulation. Pilot light and temperature indicator light. Doublewalled lid.
Continue Technical Sheet
200 L ELECTRIC BOILING PAN WITH INDIRECT HEATING
Code 20847000 - Mod E9P20I
Worktop, front and side panels made of AISI 304 stainless steel. Inside made of stainless steel.AISI 304 stainless steel cooking container with 15/10 thickness, AISI 316 stainless steel bottom with 20/10 thickness. Jacket with bottom and walls of AISI 304 stainless steel, bottom with 20/10 thickness, walls with 15/10 thickness. Indirect type heating with low pressure steam (0.5 bar) generated inside the jacket through armored resistance from Incoloy equipped with a safety thermostat. Hot and cold water taps on the worktop with an articulated spout for filling and washing the container and jacket. 2” draining tap of chromed brass with athermic handle. Mechanical gauge with a jacket pressure indicator. Power supply regulated by a 3-position switch. Separate control for temperature regulation. Pilot light and temperature indicator light. Doublewalled lid.
Continue Technical Sheet
100 L ELECTRIC BOILING PAN WITH INDIRECT HEATING(PRESSURE TANK)
Code 20833200 - Mod E9P10IA
Worktop, front and side panels made of AISI 304 stainless steel. Inside made of stainless steel.AISI 304 stainless steel cooking container with 15/10 thickness, AISI 316 stainless steel bottom with 20/10 thickness. Jacket with bottom and walls of AISI 304 stainless steel, bottom with 20/10 thickness, walls with 15/10 thickness. Indirect type heating with low pressure steam (0.5 bar) generated inside the jacket through armored resistance from Incoloy equipped with a safety thermostat. Hot and cold water taps on the worktop with an articulated spout for filling and washing the container and jacket. 2” draining tap of chromed brass with athermic handle. Four screw fixing blocks that can be adjusted manually with a fixed calibration valve of 0.05 bar. Mechanical gauge with a jacket pressure indicator. Power supply regulated by a 3-position switch. Separate control for temperature regulation. Separate control for temperature regulation. Pilot light and temperature indicator light.
Continue Technical Sheet
150 L ELECTRIC BOILING PAN WITH INDIRECT HEATING (PRESSURE TANK)
Code 20843200 - Mod E9P15IA
Worktop, front and side panels made of AISI 304 stainless steel. Inside made of stainless steel.AISI 304 stainless steel cooking container with 15/10 thickness, AISI 316 stainless steel bottom with 20/10 thickness. Jacket with bottom and walls of AISI 304 stainless steel, bottom with 20/10 thickness, walls with 15/10 thickness. Indirect type heating with low pressure steam (0.5 bar) generated inside the jacket through armored resistance from Incoloy equipped with a safety thermostat. Hot and cold water taps on the worktop with an articulated spout for filling and washing the container and jacket. 2” draining tap of chromed brass with athermic handle. Four screw fixing blocks that can be adjusted manually with a fixed calibration valve of 0.05 bar. Mechanical gauge with a jacket pressure indicator. Power supply regulated by a 3-position switch. Separate control for temperature regulation. Separate control for temperature regulation. Pilot light and temperature indicator light.
Continue Technical Sheet
200 L ELECTRIC BOILING PAN WITH INDIRECT HEATING (PRESSURE TANK)
Code 20847200 - Mod E9P20IA
Worktop, front and side panels made of AISI 304 stainless steel. Inside made of stainless steel.AISI 304 stainless steel cooking container with 15/10 thickness, AISI 316 stainless steel bottom with 20/10 thickness. Jacket with bottom and walls of AISI 304 stainless steel, bottom with 20/10 thickness, walls with 15/10 thickness. Indirect type heating with low pressure steam (0.5 bar) generated inside the jacket through armored resistance from Incoloy equipped with a safety thermostat. Hot and cold water taps on the worktop with an articulated spout for filling and washing the container and jacket. 2” draining tap of chromed brass with athermic handle. Four screw fixing blocks that can be adjusted manually with a fixed calibration valve of 0.05 bar. Mechanical gauge with a jacket pressure indicator. Power supply regulated by a 3-position switch. Separate control for temperature regulation. Separate control for temperature regulation. Pilot light and temperature indicator light.
Continue Technical Sheet
100 L GAS BOILING PAN WITH DIRECT HEATING
Code 20832001 - Mod G9P10D
Worktop, front and side panels made of AISI 304 stainless steel. Inside made of stainless steel.AISI 304 stainless steel cooking container with 15/10 thickness, AISI 316 stainless steel bottom with 20/10 thickness. Direct heating generated by tubular stainless steel burners with optimized combustion, with thermocouple safety valve and protected pilot flame. Piezoelectric ignition with rubber protection. Hot and cold water taps on the worktop with an articulated spout for filling and washing the container. 2” draining tap of chromed brass with athermic handle. Temperature regulation by means of a handle tap to adjust the water level.
Continue Technical Sheet
150 L GAS BOILING PAN WITH DIRECT HEATING
Code 20842001 - Mod G9P15D
Worktop, front and side panels made of AISI 304 stainless steel. Inside made of stainless steel.AISI 304 stainless steel cooking container with 15/10 thickness, AISI 316 stainless steel bottom with 20/10 thickness. Direct heating generated by tubular stainless steel burners with optimized combustion, with thermocouple safety valve and protected pilot flame. Piezoelectric ignition with rubber protection. Hot and cold water taps on the worktop with an articulated spout for filling and washing the container. 2” draining tap of chromed brass with athermic handle. Temperature regulation by means of a handle tap to adjust the water level.
Continue Technical Sheet
200 L GAS BOILING PAN WITH DIRECT HEATING
Code 20846001 - Mod G9P20D
Worktop, front and side panels made of AISI 304 stainless steel. Inside made of stainless steel.AISI 304 stainless steel cooking container with 15/10 thickness, AISI 316 stainless steel bottom with 20/10 thickness. Direct heating generated by tubular stainless steel burners with optimized combustion, with thermocouple safety valve and protected pilot flame. Piezoelectric ignition with rubber protection. Hot and cold water taps on the worktop with an articulated spout for filling and washing the container. 2” draining tap of chromed brass with athermic handle. Temperature regulation by means of a handle tap to adjust the water level.
Continue Technical Sheet
100 L GAS BOILING PAN WITH INDIRECT HEATING
Code 20831001 - Mod G9P10I
Worktop, front and side panels made of AISI 304 stainless steel. Inside made of stainless steel.AISI 304 stainless steel cooking container with 15/10 thickness, AISI 316 stainless steel bottom with 20/10 thickness. Jacket with bottom and walls of AISI 304 stainless steel, bottom with 20/10 thickness, walls with 15/10 thickness. Indirect type heating with low pressure steam (0.5 bar) generated inside the jacket through tubular stainless steel burners with optimized combustion, with thermocouple safety valve and protected pilot flame. Piezoelectric ignition with rubber protection. Hot and cold water taps on the worktop with an articulated spout for filling and washing the container and the jacket. 2” draining tap of chromed brass with athermic handle. Temperature regulation by means of a handle tap to adjust the water level.
Continue Technical Sheet
150 L GAS BOILING PAN WITH INDIRECT HEATING
Code 20841001 - Mod G9P15I
Worktop, front and side panels made of AISI 304 stainless steel. Inside made of stainless steel.AISI 304 stainless steel cooking container with 15/10 thickness, AISI 316 stainless steel bottom with 20/10 thickness. Jacket with bottom and walls of AISI 304 stainless steel, bottom with 20/10 thickness, walls with 15/10 thickness. Indirect type heating with low pressure steam (0.5 bar) generated inside the jacket through tubular stainless steel burners with optimized combustion, with thermocouple safety valve and protected pilot flame. Piezoelectric ignition with rubber protection. Hot and cold water taps on the worktop with an articulated spout for filling and washing the container and the jacket. 2” draining tap of chromed brass with athermic handle. Temperature regulation by means of a handle tap to adjust the water level.
Continue Technical Sheet
100 L GAS BOILING PAN WITH DIRECT HEATING (PRESSURE TANK)
Code 20832201 - Mod G9P10DA
Worktop, front and side panels made of AISI 304 stainless steel. Inside made of stainless steel.AISI 304 stainless steel cooking container with 15/10 thickness, AISI 316 stainless steel bottom with 20/10 thickness. Direct heating generated by tubular stainless steel burners with optimized combustion, with thermocouple safety valve and protected pilot flame. Piezoelectric ignition with rubber protection. Hot and cold water taps on the worktop with an articulated spout for filling and washing the container. 2” draining tap of chromed brass with athermic handle. Four screw fixing blocks that can be adjusted manually with a fixed calibration valve of 0.05 bar. Temperature regulation by means of a handle tap to adjust the water level.
Continue Technical Sheet
150 L GAS BOILING PAN WITH DIRECT HEATING (PRESSURE TANK)
Code 20842201 - Mod G9P15DA
Worktop, front and side panels made of AISI 304 stainless steel. Inside made of stainless steel.AISI 304 stainless steel cooking container with 15/10 thickness, AISI 316 stainless steel bottom with 20/10 thickness. Direct heating generated by tubular stainless steel burners with optimized combustion, with thermocouple safety valve and protected pilot flame. Piezoelectric ignition with rubber protection. Hot and cold water taps on the worktop with an articulated spout for filling and washing the container. 2” draining tap of chromed brass with athermic handle. Four screw fixing blocks that can be adjusted manually with a fixed calibration valve of 0.05 bar. Temperature regulation by means of a handle tap to adjust the water level.
Continue Technical Sheet
200 L GAS BOILING PAN (PRESSURE TANK) WITH DIRECT HEATING
Code 20846201 - Mod G9P20DA
Worktop, front and side panels made of AISI 304 stainless steel. Inside made of stainless steel.AISI 304 stainless steel cooking container with 15/10 thickness, AISI 316 stainless steel bottom with 20/10 thickness. Direct heating generated by tubular stainless steel burners with optimized combustion, with thermocouple safety valve and protected pilot flame. Piezoelectric ignition with rubber protection. Hot and cold water taps on the worktop with an articulated spout for filling and washing the container. 2” draining tap of chromed brass with athermic handle. Four screw fixing blocks that can be adjusted manually with a fixed calibration valve of 0.05 bar. Temperature regulation by means of a handle tap to adjust the water level.
Continue Technical Sheet
100 L GAS BOILING PAN WITH INDIRECT HEATING (PRESSURE TANK)
Code 20831201 - Mod G9P10IA
Worktop, front and side panels made of AISI 304 stainless steel. Inside made of stainless steel.AISI 304 stainless steel cooking container with 15/10 thickness, AISI 316 stainless steel bottom with 20/10 thickness. Jacket with bottom and walls of AISI 304 stainless steel, bottom with 20/10 thickness, walls with 15/10 thickness. Indirect type heating with low pressure steam (0.5 bar) generated inside the jacket through tubular stainless steel burners with optimized combustion, with thermocouple safety valve and protected pilot flame. Piezoelectric ignition with rubber protection. Hot and cold water taps on the worktop with an articulated spout for filling and washing the container and the jacket. 2” draining tap of chromed brass with athermic handle. Four screw fixing blocks that can be adjusted manually with a fixed calibration valve of 0.05 bar. Temperature regulation by means of a handle tap to adjust the water level.
Continue Technical Sheet
150 L GAS BOILING PAN WITH INDIRECT HEATING (PRESSURE TANK)
Code 20841201 - Mod G9P15IA
Worktop, front and side panels made of AISI 304 stainless steel. Inside made of stainless steel.AISI 304 stainless steel cooking container with 15/10 thickness, AISI 316 stainless steel bottom with 20/10 thickness. Jacket with bottom and walls of AISI 304 stainless steel, bottom with 20/10 thickness, walls with 15/10 thickness. Indirect type heating with low pressure steam (0.5 bar) generated inside the jacket through tubular stainless steel burners with optimized combustion, with thermocouple safety valve and protected pilot flame. Piezoelectric ignition with rubber protection. Hot and cold water taps on the worktop with an articulated spout for filling and washing the container and the jacket. 2” draining tap of chromed brass with athermic handle. Four screw fixing blocks that can be adjusted manually with a fixed calibration valve of 0.05 bar. Temperature regulation by means of a handle tap to adjust the water level.
Continue Technical Sheet
200 L GAS BOILING PAN WITH INDIRECT HEATING
Code 20845001 - Mod G9P20I1
Worktop, front and side panels made of AISI 304 stainless steel. Inside made of stainless steel.AISI 304 stainless steel cooking container with 15/10 thickness, AISI 316 stainless steel bottom with 20/10 thickness. Jacket with bottom and walls of AISI 304 stainless steel, bottom with 20/10 thickness, walls with 15/10 thickness. Indirect type heating with low pressure steam (0.5 bar) generated inside the jacket through tubular stainless steel burners with optimized combustion, with thermocouple safety valve and protected pilot flame. Piezoelectric ignition with rubber protection. Hot and cold water taps on the worktop with an articulated spout for filling and washing the container and the jacket. 2” draining tap of chromed brass with athermic handle. Temperature regulation by means of a handle tap to adjust the water level.
Continue Technical Sheet
200 L GAS BOILING PAN WITH INDIRECT HEATING (PRESSURE TANK)
Code 20845201 - Mod G9P20I1A
Worktop, front and side panels made of AISI 304 stainless steel. Inside made of stainless steel.AISI 304 stainless steel cooking container with 15/10 thickness, AISI 316 stainless steel bottom with 20/10 thickness. Jacket with bottom and walls of AISI 304 stainless steel, bottom with 20/10 thickness, walls with 15/10 thickness. Indirect type heating with low pressure steam (0.5 bar) generated inside the jacket through tubular stainless steel burners with optimized combustion, with thermocouple safety valve and protected pilot flame. Piezoelectric ignition with rubber protection. Hot and cold water taps on the worktop with an articulated spout for filling and washing the container and the jacket. 2” draining tap of chromed brass with athermic handle. Four screw fixing blocks that can be adjusted manually with a fixed calibration valve of 0.05 bar. Temperature regulation by means of a handle tap to adjust the water level.
Continue Technical Sheet
200 LT BOILING PAN WITH INDIRECT STEAM HEATING
Code 20848000 - Mod 9P20IV
Worktop, front and side panels in AISI 304 stainless steel. AISI 304 stainless steel cooking tank (15/10 thick), AISI 316 stainless steel bottom (20/10 thick).
Indirect steam heating.
Hot and cold water taps on the worktop with an articulated spout for filling and washing the tank.
2” chromed brass draining tap of with heatless handle.
Cooking temperature optimization by means of a valve for the steam flow adjustment.
Continue Technical Sheet
200 LT BOILING PAN WITH INDIRECT STEAM HEATING (PRESSURE TANK)
Code 20848200 - Mod 9P20IVA
Worktop, front and side panels in AISI 304 stainless steel. AISI 304 stainless steel cooking tank (15/10 thick), AISI 316 stainless steel bottom (20/10 thick).
Indirect steam heating.
Hot and cold water taps on the worktop with an articulated spout for filling and washing the tank.
2” chromed brass draining tap of with heatless handle.
Cooking temperature optimization by means of a valve for the steam flow adjustment.
Four screw fixing blocks that can be adjusted manually with a fixed calibration valve of 0.05 bar.
Continue Technical Sheet
 

BERTO'S: EXCELLENT PROFESSIONAL COOKERS

40 years of passion, experience, research and development with a sole aim. Create the perfect cooker … yours!
PARTNERSHIPS
All of Berto's partners are the leaders in their specific fields
 
 
PROJECTS
Each Berto's Cooker is designed and processed with care down to the smallest details
 
 
CONTACT US
For information, advice or assistance
You are always welcome!
 
 
Work with Us
If you would like to join the Berto's world, send us your resume
 
 
 
Certifications
 
 
 
 
Newsletter
 
Stay informed about Berto's